Published July 8, 2026 at 22:28
Cylindrical workpieces present one of the fundamental geometric challenges in the workshop environment. Flat clamped parts (blocks, plates) hold easily between parallel vice jaws; cylindrical parts roll. This simple physical difference has driven the development of V-blocks — a classic workshop fixture that uses the geometric property of a 90° V-groove to automatically center cylindrical workpieces. The modern magnetic V-block combines this geometry with controllable magnetic holding force — eliminating the need for mechanical clamps and making positioning and moving workpieces much faster.
What the Schut magnetic V-block is
Magnetic V-block, dimensions 100×70×95 mm, capacity Ø6-55 mm, magnetic force 1178 N, weight 3.7 kg (art. 906.208) from Schut ECONOMY LINE is a professional magnetic V-block for setting up and inspecting cylindrical workpieces. The instrument:
- Has overall dimensions of 100×70×95 mm.
- Has a V-groove with a 90° opening angle.
- Fits shafts and cylindrical workpieces Ø6-55 mm.
- Has a magnetic force of 1178 N (~120 kg holding force).
- Has an on/off switch to activate/deactivate the magnet.
- Weighs 3.7 kg (providing stability).
- Has a hardened steel construction with ground reference surfaces.
- Can be used alone or in pairs for long workpiece fixturing.
- Is compatible with ISO 17025 calibration certificates.
Basic specifications:
- Manufacturer: Schut (Germany)
- Series: ECONOMY LINE
- Type: Magnetic V-block
- Dimensions: 100 × 70 × 95 mm
- V-groove opening angle: 90°
- Capacity: Ø6-55 mm (cylindrical workpiece)
- Magnetic force: 1178 N (~120 kg pull)
- Weight: 3.7 kg
- Activation: On/off switch
- Material: Hardened steel, ground
- Article number: 64-906208
V-groove geometry and self-centering
The basic principle of the V-groove: two angled surfaces meeting at a fixed opening angle (typically 90°). When a cylinder is placed in the groove, it rests against BOTH surfaces — and these two contact points are equidistant from the V-groove’s line of symmetry.
Geometric consequence: the cylinder’s axis lies PRECISELY in the groove’s plane of symmetry, regardless of the cylinder’s diameter (as long as it fits within the capacity range). This self-centering property is the fundamental reason V-blocks are standard equipment in every workshop metrology lab.
For a 90° V-groove:
- Cylinder axis height above the V-groove bottom = R × √2 (where R = cylinder radius).
- For a Ø10 mm cylinder (R=5): axis height 5 × 1.414 = 7.07 mm.
- For a Ø50 mm cylinder (R=25): axis height 25 × 1.414 = 35.36 mm.
The height variation with cylinder size is predictable and can be compensated for in measurement or marking-out work.
Magnetic holding — how it works
Traditional V-blocks without magnetic force require mechanical clamps or manual holding to keep the workpiece in the groove. Magnetic V-blocks use built-in permanent magnets (typically NdFeB, neodymium-iron-boron) with an activation mechanism:
- Off position: The magnets are internally “short-circuited” against a steel locking arm. Magnetic flux stays inside the block, not directed toward the V-groove.
- On position: The locking arm is rotated, redirecting the magnetic flux out through the V-groove.
- The cylinder is clamped: Ferromagnetic cylinders (steel, cast iron) are attracted to the V-groove with 1178 N of force.
The advantages:
- No mechanical clamps that could scratch or mark the workpiece.
- Fast positioning — the cylinder “clicks” into place.
- Uniform pressure from the magnet ensures consistent contact with the V-groove surfaces.
- Instant release by flipping the on/off switch — much faster than loosening clamps.
Limitation: works only with ferromagnetic workpieces. Aluminum, brass, plastic, or stainless steel (grade 304, 316) are not held.
Compatible workpieces
The Ø6-55 mm capacity covers most typical cylindrical workpieces:
- Motor shafts and pump shafts (typically Ø15-40 mm).
- Bench fittings and bearing inserts.
- Hydraulic cylinders and pneumatic rods.
- Precision bolts and threaded rods.
- Precision pins and cylindrical machine parts.
- Roller bearings (free of grease contamination).
For larger workpieces (>55 mm), dedicated larger V-blocks are required. For smaller ones (<6 mm), contact with the V-groove is insufficient for stability.
Workshop applications
Marking out on cylindrical workpieces: The V-block holds the workpiece stable while the operator marks length positions with a height gauge or marking-out block.
Inspection with a dial indicator: The cylinder is fixed in place, and the indicator is run along it to measure roundness and cylindricity.
Drilling/tapping: Radial hole drilling on a drill press requires precise shaft centering. The V-block provides this.
Grinding of threads or surfaces: A short workpiece can be held between two V-blocks for grinding.
Calibration verification: Reference cylinders for calibrating internal measuring instruments.
QC of shaft diameters and cylindricity: Measuring microscope over a V-block-mounted shaft.
Material analysis: Hardness testing (Rockwell, Brinell) on a cylindrical workpiece requires V-block support.
Teaching workshop metrology: A fundamental demonstration tool.
Reverse engineering of existing components: Precise dimensional measurements of legacy machine parts.
Prototype and research fabrication: New components require precise setup.
Paired use for long workpieces
For long cylindrical workpieces (>100 mm), two V-blocks are typically used, placed at the ends of the workpiece. This offers several advantages:
- The workpiece is supported at two points, giving stable positioning.
- Workpiece bending can be detected — if the axis height at V-block 1 differs from V-block 2, the workpiece is not straight.
- Longer workpieces don’t fit on a single short V-block alone.
The Schut V-block is typically sold individually, so two units must be purchased if paired use is needed.
Precision tolerances
V-block tolerances critical for precision inspection:
- Flatness of the V-groove surfaces: Typically 0.003-0.005 mm over a 50 mm length.
- 90° angular accuracy: ±30″ (arc seconds), corresponding to ±5 µm at a 20 mm cylinder height.
- Parallelism between groove bottom and block base: Critical for height measurement. Typically 0.005 mm.
- Perpendicularity between V-groove and block sides: 0.005 mm.
Class 0 V-blocks (calibration-lab grade) have 2-3× tighter tolerances but cost correspondingly more.
Maintenance
- Clean the V-groove after each use: Metal chips or oil damage the magnetic contact and can scratch workpieces.
- Off position during storage: Reduces magnet wear. Deactivation makes the V-block safe to handle without risk of trapped metal fragments.
- Protect against drops and impact: Ground reference surfaces are precise; impacts can cause permanent deviations.
- Thermal stability: Use at 20 °C ±2 °C. Extremely hot or cold environments can affect magnet strength.
- Annual calibration verification: The V-groove’s angle and flatness should be verified against reference standards.
What you get for the money
Schut ECONOMY LINE magnetic V-block 906.208, dimensions 100×70×95 mm, capacity Ø6-55 mm cylindrical workpiece, 90° V-groove with self-centering geometry, magnetic force 1178 N (~120 kg pull) via NdFeB permanent magnets, on/off activation with a rotary switch, hardened steel construction with ground reference surfaces, 3.7 kg weight for stability, compatible with ISO 17025 calibration certificates.
919 DKK is the instrument investment. Compared to a non-magnetic V-block (300-600 DKK, requiring separate clamps), the price premium is minimal and the workflow benefits are significant. Compared to a precision fixture with hydraulic clamping (5,000-15,000 DKK, heavy and complex), the magnetic V-block is portable and sufficient for most workshop tasks.
Read more: Schut magnetic V-block 906.208 in the shop →