Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trust

A thermometer reading 72 °C could be several degrees off: how to check it in a few minutes

Published 22 November 2026 at 13:02

The check shows 72 °C, and the batch is released. But when was the thermometer last compared against something known to be correct? In most places the answer is a guess. Thermometers get dropped, exposed to thermal shock and cleaned harshly, and the deviation creeps in without anyone noticing.

ETI Kalibrator model 3003 for thermometers, the calibrator is supplied with a calibration certificate and works with so-called dry blocks, with hole sizes Ø4.76 and 12.7 mm, and generates temperatures within ±0.5 °C between 33 °C - 250 °C

What is a dry-block calibrator

The ETI Kalibrator model 3003 is a small, portable heat source in which a metal block is held at a set, stable temperature. You insert the probes into the holes in the block and compare the thermometer’s reading with the calibrator’s display. The difference is the thermometer’s error. The model covers 33 to 250 °C with a resolution of 0.1 °C and a stability of ±0.5 °C up to 199.9 °C (±1 °C from 200 to 250 °C). The holes are Ø4.76 and Ø12.7 mm, and the well depth is 100 mm. It weighs 950 g and is supplied with a traceable calibration certificate.

What problem does it solve

Without a reference, all you know is that the thermometer shows a number, not that the number is correct. Ice water is a good fixed point at 0 °C, but it says nothing about the range around 75, 120 or 180 °C, where many processes actually operate. A dry-block calibrator lets you check precisely the temperatures that are critical to you, without sending the equipment away and doing without it for several weeks.

How to use it

You plug it in, set the verification temperature with the buttons on the front panel and let the block stabilise. The manufacturer specifies a stabilisation time of about five minutes. Then you insert the probe so that it sits snugly in the hole, and compare the readings. Remember to check the probe’s diameter against the two hole sizes before choosing a model.

Three real-world situations

Food production. Core and cooking temperatures are part of the HACCP plan. A periodic check of probes and handheld thermometers at, for example, 75 °C provides a documented basis when an auditor asks.

Production and maintenance. Curing ovens, heat presses and processes with temperature sensors drift over time. A quick check in the workshop reveals whether a sensor needs adjusting or replacing before the products show it.

Quality and laboratory. Where several handheld thermometers are in circulation, an internal interim check between the external calibrations can show which instruments are starting to deviate.

Why it pays off

The price is just under DKK 15,000, but the comparison is not a new thermometer. It is a faulty batch, a rejection or a remark in an audit because a measurement could not be documented. Add to that the time lost when thermometers are otherwise sent for external checks and are missing in day-to-day work. With a calibrator at hand, the check becomes a routine of a few minutes rather than a project.