Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to document temperature and humidity during transport without installing softwareDeep holes are rarely round all the way down: how to map ovality and taper at 1000 mmThe cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to document temperature and humidity during transport without installing softwareDeep holes are rarely round all the way down: how to map ovality and taper at 1000 mmThe cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak link
Item number 76-1502882-040

Compact Dry YM – for yeast and mold – 40 test plates per pack, 38210000, Japan

714 DKK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating medium waste as well as the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests.
Request a quote 76-1502882-040

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

With Compact Dry YM, yeast and mold can be differentiated by color development. The medium contains the chromogenic enzyme substrate X-Phos, which turns blue with many yeast species. Molds form fluffy colonies with a characteristic color. Antibiotics inhibit bacterial growth. Compact Dry YM enables very good 3-dimensional growth of yeast and mold. Compact Dry YM is AOAC-approved.


Incubation time and temperature: 3 – 7 days at 25 – 30 °C
Shelf life: 18 months after manufacture
Storage: Room temperature (+ 1 to + 30 °C)


Sample preparation Viable count in water or liquid food
Dispense 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.
Viable count in solid food
Add buffer solution to the sample and homogenize with a Stomacher®. Dispense 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use a cotton swab to wipe the surface, insert it into the device with the elution solution. Dispense 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate. It is recommended to use “Swab for Compact Dry” offered by HyServe ID no. 1 002 952/3 (40/240 pieces)

Test instructions
1. Open the lid and dispense 1 ml of sample onto the center of the Compact Dry plate.
2. The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within seconds.
3. Replace the lid on the plate and write the necessary information in the memo section.
4. Turn the covered plate upside down and place it in the incubator.
5. After incubation, count the number of colored colonies under the plate. White paper placed under the plate helps in counting the colonies.