Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to document temperature and humidity during transport without installing softwareDeep holes are rarely round all the way down: how to map ovality and taper at 1000 mmThe cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to document temperature and humidity during transport without installing softwareDeep holes are rarely round all the way down: how to map ovality and taper at 1000 mmThe cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak link
Item number 79-15000062-001

Allergen Elisa II Kit: Casein Allergen Test for 96 determinations, 38221900, Japan

5.149 DKK

In stock
  • Allergen detection in highly processed and heated foods
  • High sensitivity (lod: 0.31 ppm)
  • High specificity
  • Easy-to-use protocols
Request a quote 79-15000062-001

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: ,

Description

79-15000062-001 Test allergens > ELISA II

These ELISA kits are sandwich enzyme immunoassays for the quantitative determination of individual proteins from allergenic ingredients in processed or unprocessed food. These kits are designed for use by quality control personnel or other trained professionals, for allergen monitoring in production or for product release controls.
Proteins in the samples are extracted, centrifuged, and filtered prior to the sandwich ELISA. The antigen is bound to the polyclonal antibody-coated wells in the microplate module, resulting in an antigen-antibody complex. Subsequently, the enzyme-conjugated antibody binds to the already bound antigen-antibody complex, forming an antibody-antigen-antibody sandwich.
Addition of the enzyme substrate results in color development, the intensity of which can be determined by absorbance at 450 nm. The intensity of the developed color is directly proportional to the concentration of protein from allergenic ingredients in the food.

1 x 96-well microplates (12 strips of 8 wells)
Associated buffers and enzymes


Measurement time:
Sample preparation time: Approximately 10 min
Sample extraction time: Approximately 30 min, or overnight
ELISA analysis: Approximately 2 hours
Analysis sensitivity: 0.31 ppm (μg protein /g food)
Detectable concentration range: 0.78 to 50 ppb detectable protein
Storage: At 2-8 °C (35-46 °F), DO NOT FREEZE
Working temperature: 20-30 °C (all solutions must be equilibrated)


Extraction procedure Short-term extraction method
Grind/finely divide the samples
Weigh 1.0 g of sample into a tube, add 19 ml of sample extraction solution.
Incubate the capped tube in boiling water for 10 minutes.
Cool the tube and vortex for 30 seconds.
Adjust pH to 6.0-8.0.
Centrifuge and filter the supernatant if necessary.
Dilute the sample extract 20-fold with dilution buffer I.
Overnight extraction method
Grind/finely divide the samples
Weigh 1.0 g of sample into a tube, add 19 ml of sample extraction solution.
Attach the tube horizontally to a shaker and shake at room temperature overnight.
Adjust pH to 6.0-8.0.
Centrifuge and filter the supernatant if necessary.
Dilute the sample extract 20-fold with dilution buffer I.
ELISA procedure
Pipette 100 μL of working standard and working sample solution into a well of the microplate.
Incubate the microplate for 1 hour at 20-30 °C (68-86 °F).
Wash the wells 6 times with wash solution.
Dispense 100 μL of enzyme-conjugated antibody (F).
Incubate the microplate for 30 minutes at 20-30 °C (68-86 °F).
Wash the wells 6 times.
Dispense 100 μL of enzyme substrate (G).
Incubate the reaction for 20 minutes at 20-30 °C (68-86 °F) in the dark.
Stop the enzyme reaction by adding 100 μL of stop solution (H).
Measure the absorbance at 450 nm.
Calculate the concentration of the detectable protein using the standard curve.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *