Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cable
Item number 76-1502991-040

Compact Dry BC – for Bacillus Cereus – 40 test plates per pack, 38210000, Japan

731 DKK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium as well as the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests
Request a quote 76-1502991-040

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

The “Ready-to-use” Compact Dry X-BC plate from HyServe combines the properties of chromogenic dry media and gel contact plates. It is used for the quantitative detection of Bacillus cereus in food samples. The bacterium Bacillus cereus produces gram-positive spores and is commonly found in soil and water. Consequently, it relatively easily enters the food processing chain. Bacillus cereus can contaminate food; furthermore, its emetic and diarrheagenic enterotoxins cause vomiting and diarrhea after consumption. Routine testing procedures for Bacillus cereus are therefore recommended. A simple and certified method for this is: Compact Dry X-BC. After application of the sample (1 ml), the dehydrated Compact Dry X-BC plate becomes gel-like. The sample self-diffuses evenly. No further actions, such as manual spreading, are required.
Compact Dry X-BC has been validated according to ISO 16140 against the reference method (EN ISO 7932:2004) for the detection of Bacillus cereus. Compact Dry X-BC is also MicroVal (no. 2011-LR41) and NordVal (no. 045) approved. The finished plate can therefore be applied routinely by certified users.


Incubation time and temperature: 24 ± 2 hours at 30 ± 1 °C
Shelf life: 18 months after manufacture.
Storage: Room temperature (+ 1 to + 30 °C)


Sample preparation Viable count

in water or liquid food
Drop 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.

Viable count in solid food
Add buffer solution to the sample and homogenize with a stomacher®. Drop 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.

Viable count in swab test samples
Use the cotton swab to wipe the surface, insert it into the unit with elution solution. Drop 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate. It is recommended to use “Swab for Compact Dry” offered by HyServe ID no. 1 002 952/3 (40/240 pieces).

Test instructions

Open the lid and drop 1 ml of sample onto the center of the Compact Dry plate.
The sample automatically and evenly diffuses into the pad, converting the dried pad into a gel within a few seconds.
Replace the lid on the plate and write the necessary information on the memo section.
Turn the covered plate upside down and place it in the incubator.
After incubation, count the number of light blue/blue colonies. Placing white paper under the plate helps in counting the colonies.