Hoppa till innehåll
Free shipping over 3.738 DKK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%See the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%See the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator error
Item number 76-1000889

Dilution Stand for Compact Dry – MRD, 128 containers per box, each with 9 ml, 38221900, Japan

851 DKK

In stock
  • Simple preparation of a dilution series
  • Distributed diluent
  • Time- and cost-effective
  • Storage at room temperature
Request a quote 76-1000889

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

The Dilution Rack – mrd for Compact Dry helps you dilute samples efficiently and quickly, without additional time-consuming preparations. It is delivered sterile and ready to use.

The PBS Dilution Rack contains a maximum recovery solution for sensitive materials and analyses.

By adding 1 ml of sample to the first well, mixing, and transferring 1 ml from that well to the next, a 1:10 dilution series is prepared very easily.

128 wells in 32 racks with 4 separable wells each (9 ml each)


Punch two holes in the foil on each of the wells.

After preparing the homogenized sample, release 1 ml of the sample with a sterile pipette into the well through one of the holes. (for a ten-fold dilution, 10-1)

Mix by pipetting up and down.

Using a new pipette, enter through the second punched hole, draw up 1 ml, and transfer to a Compact Dry plate (see below).

To generate further dilutions, transfer 1 ml of sample to the next well (dilution 10-2) and so on. Repeat this step until you reach the calculated dilution.

Specification

The Dilution Rack – mrd for Compact Dry helps you dilute samples efficiently and quickly, without additional time-consuming preparations. It is delivered sterile and ready to use.

The PBS Dilution Rack contains a maximum recovery solution for sensitive materials and analyses.

By adding 1 ml of sample to the first well, mixing, and transferring 1 ml from that well to the next, a 1:10 dilution series is prepared very easily.

128 wells in 32 racks with 4 separable wells each (9 ml each)


Punch two holes in the foil on each of the wells.

After preparing the homogenized sample, release 1 ml of the sample with a sterile pipette into the well through one of the holes. (for a ten-fold dilution, 10-1)

Mix by pipetting up and down.

Using a new pipette, enter through the second punched hole, draw up 1 ml, and transfer to a Compact Dry plate (see below).

To generate further dilutions, transfer 1 ml of sample to the next well (dilution 10-2) and so on. Repeat this step until you reach the calculated dilution.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *