Hoppa till innehåll
Free shipping over 3.738 DKK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%See the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%See the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator error
Item number 76-1502889-040

Compact Dry ETB – for enterobacteria – 40 test plates per pack, 38210000, Japan

619 DKK

In stock
  • Clear and easy-to-use portable plate: No medium preparation is required, eliminating waste of medium as well as the need for sterilization equipment to prepare the medium.
  • Detection of colonies on the plate is simple and clear.
  • Individual colonies on the plate can be isolated for further identification tests
Request a quote 76-1502889-040

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

ETB refers to Enterobacteria, which are Gram-negative, rod-shaped bacteria. Compact Dry ETB is a ready-to-use, chromogenic Compact Dry plate suitable for both process and finished product control. Using Compact Dry ETB makes it very easy to detect Enterobacteriaceae. Its substrate allows for easy differentiation of Enterobacteria from other groups.


Incubation time and temperature: 24 ± 2 hours at 37 ± 1 °C
Shelf life: Room temperature (+ 1 to + 30 °C)
Storage: 16 months after manufacture.


Sample preparation
Viable count in water or liquid food
Dispense 1 ml of sample (dilute if necessary) onto the center of the Compact Dry plate.
Viable count in solid food
Add buffer solution (e.g., 0.9% saline, PBS, buffered peptone water, etc.) to the sample and homogenize with a Stomacher®. Dispense 1 ml of sample (dilute if necessary) onto the center of the dry pad on the Compact Dry plate.
Viable count in swab test samples
Use a sterile wet wipe to wipe the surface to be analyzed and return it to the unit with the elution solution.
After shaking the unit (approx. 10 seconds), dispense 1 ml of elution solution (dilute if necessary) onto the center of the Compact Dry plate.
Use Compact Dry Swab (art. No. ZCS1002953, content 40 pcs) as a single-use applicator (1 ml) or Promedia ST-25 (art. No. Z0302, content 10 pcs) as a multiple applicator (10 ml) for this procedure.

Test instructions

Open the top lid of the Compact Dry plate. Dispense 1 ml of sample in the center of the plate.
The sample automatically and evenly diffuses into the pad, converting the dry pad into a gel within seconds.
Close the lid on the plate and place it in the incubator in a horizontal position
After incubation, count the number of all grown colonies on the plate.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *