Hoppa till innehåll
Free shipping over 3.738 DKK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator Uncertainty

Kroeplin Intertest H260 internal measuring instrument 60-80 mm: When the hydraulic cylinder bore needs to be measured in 3 seconds with 3-jaw self-centering instead of 30 seconds with a Holtest

Published July 13, 2026 at 23:02

Internal bore measurement is one of the toughest tasks in workshop metrology. Calipers can’t reach into deep bores. A dial bore gauge with internal jaws only provides 2-line contact (misses ovality). A standard 2-point internal micrometer requires operator skill to hold perpendicular in the bore. A 3-point Holtest solves the geometry problem but is slow and more expensive.

Kroeplin Intertest is a completely different philosophy: build an instrument designed for SPEED with acceptable precision, not for maximum precision with acceptable speed. The target audience is series production where 100-500 bores need to be measured per shift and ±0.03 mm tolerance is sufficient.

3-jaw self-centering at 120°

The H260 has three measuring jaws positioned at 120° angular spacing around the instrument axis. The jaws move SIMULTANEOUSLY and SYMMETRICALLY outward via a precision cam mechanism.

The physics behind it: three points in a 120° formation geometrically define a circle unambiguously. No matter where the operator inserts the instrument into the bore, all three jaws CANNOT touch anything simultaneously other than the maximally inscribed circle. Ovality and local deformation are automatically averaged out.

This means two things:

  1. No operator tilt error: Even if the instrument is held slightly askew, all three jaws give the same diameter value.
  2. Ovality is detected: By rotating the instrument 60° and repeating the measurement, the ovality appears as the difference between two readings.

The cam mechanism is designed so that the jaws’ 120° angular spacing is MAINTAINED throughout the entire diameter sweep (60-80 mm in this model). A cheaper design would let the angles drift from 120° to e.g. 115°/125° further from mid-range — which would destroy the self-centering effect.

Integrated dial indicator — no separately mounted indicator

Traditional internal measuring instruments (e.g. cheap tolerance-mechanical types) require a separate dial indicator that is mounted on top. The advantage: the same indicator can be used on multiple instruments. The disadvantage: mounting friction and backlash affect the reading.

The Intertest series has the dial indicator INTEGRATED into the instrument body. Advantages:

  • No mounting slack — the instrument is calibrated as a single unit.
  • The indicator drive shaft is short and rigid (zero backlash).
  • Manufacturing tolerance is tighter than a looser component assembly.
  • Clear direct reading without a transfer mechanism.

Zeroing against a setting ring

The H260 does not give an absolute diameter reading — it gives a DEVIATION from a reference. Procedure:

  1. Place the instrument in a calibration setting ring with nominal diameter (e.g. 70 mm for the H260).
  2. Zero the dial indicator at this position.
  3. Insert the instrument into the actual bore.
  4. Read the deviation from 70 mm: +0.03 mm means the bore is 70.03 mm; -0.05 mm means 69.95 mm.

Practical consequence: the instrument works best for VERIFICATION of a specific bore-diameter tolerance, not for discovering the diameter from unknown measurements. If the series switches from 70 mm bores to 75 mm bores, a new setting ring must be used for zeroing.

Measuring range 60-80 mm — how does it work?

Even though zeroing occurs at e.g. 70 mm, the H260 can still MEASURE deviations from 60 to 80 mm ± a certain margin. The dial indicator has a travel range of ±3-5 mm, which means:

  • Zero at a 65 mm ring → can measure 62-68 mm bores.
  • Zero at a 70 mm ring → can measure 67-73 mm bores.
  • Zero at a 75 mm ring → can measure 72-78 mm bores.

To cover the entire 60-80 mm range, you typically need 3-4 different setting rings. Standard stock is 65/70/75 mm.

Speed vs. precision — when to choose what

Choose Kroeplin Intertest when:

  • Series production (100+ bores per shift).
  • Standard tolerance H7 or looser (typically ±25-50 μm).
  • Operator has limited metrology training.
  • Measuring time per bore under 10 seconds is critical.

Choose 3-point Holtest when:

  • Prototype or single-batch verification.
  • Tight tolerance H6 or better (±10 μm or less).
  • An absolute diameter value is required (not just “OK/not OK”).
  • Measurements are few and precision requirements dominate over speed.

Choose a standard internal micrometer when:

  • Infrequent use — not daily production.
  • Budget constraint (costs DKK 1,500-3,500).
  • Field use where jig fixtures for a reference ring are impractical.

Applications

Hydraulic cylinder production: Standard hydraulic cylinders have a 60-80 mm internal diameter for aerospace servos and agricultural hydraulics. Series production of 500-1000 cylinders per shift. The H260 provides 3-second acceptance tests.

Machined housing bore inspection: Engine housings (cylinder liners), pump housings (impeller bearings), gearboxes (shaft bearings). The H260 verifies that a CNC-drilled bore is within tolerance without stopping production for each unit.

Bushing wear control: Bronze bushings in heavy machinery wear over time. Periodic measurement with the H260 gives the wear rate and predicts the replacement time.

Line-side QC: A series production line has a QC station where every 5th-10th unit is tested. The H260 adapts to the line’s cycle time.

Blind-feature inspection: Holes that don’t go all the way through (blind holes) can only be measured from one side. The H260’s compact head reaches into blind holes up to 100 mm deep.

Rugged construction

The H260 is rated shock- and impact-resistant, dust- and water-tight (IP rating not explicitly specified but typically IP54 for Kroeplin Intertest). This sets it apart from precision lab instruments like the Mitutoyo Holtest, which require clean surroundings.

Practical consequence: the H260 can be used on:

  • Workshop floors with swarf, oil, coolant.
  • Construction sites with dust and moisture.
  • Marine shipyard environments with salt water.
  • Mining and tunnel work with dirt and dust.

A standard 3-point Holtest would require a clean-room lab and daily calibration in these environments.

Adjustable tolerance markers

The dial indicator has adjustable tolerance pointers (red/green markers) that are set to the workpiece’s upper and lower tolerance. During measurement the operator sees directly:

  • Green zone: reading within tolerance — accepted.
  • Red zone: out of tolerance — rejected.

No mental calculation required. The operator sees: “green” → OK, “red” → scrap/rework. Perfect for less-experienced operators in series production.

Specifications

  • Measuring range: 60-80 mm internal diameter.
  • Graduation: 0.01 mm.
  • Accuracy: ±0.03 mm.
  • Repeatability: 0.01 mm.
  • Measuring method: 3-jaw self-centering at 120°.
  • Dial indicator: integrated into the instrument body.
  • Rugged: shock- and impact-resistant, dust- and splash-tight.
  • Adjustable tolerance markers.
  • Requires a separate setting ring for zeroing (sold separately).

What you get for the money

Kroeplin Intertest H260 internal measuring instrument, measuring range 60-80 mm internal diameter, 3-jaw self-centering at 120° angular spacing, integrated dial indicator with 0.01 mm graduation, ±0.03 mm accuracy, 0.01 mm repeatability, adjustable tolerance markers, rugged shock-/impact-resistant dust-/splash-tight construction. DKK 3,948. (Setting ring sold separately.)

The standard tool for series-production QC on hydraulic cylinders, engine housings, gearboxes, and other 60-80 mm internal diameters where speed outweighs maximum precision. The premium over a cheap standard internal micrometer (DKK 1,500-2,500) is justified for any series-production application measuring more than 50 bores per day — the time savings of 20-30 seconds per bore pays back the instrument within a few months.

Read more: Kroeplin Intertest H260 60-80 mm in the shop →

More news

All news