Published 16 October 2026 at 05:21
Two colleagues measure the same bore and get two different numbers. The difference is only a few hundredths of a millimetre, but it is enough for one of them to reject a hydraulic cylinder that the other approves. The fault rarely lies in the bore. It lies in how the measuring instrument is held and how skewed it has sat in the bore.
A Micrometer That Centers Itself
The Holtest-type internal three-point micrometer has three measuring jaws positioned 120° apart around the axis. When the jaws expand, the instrument finds the center of the bore by itself. The operator does not have to guess whether the instrument is perpendicular or whether he has found the largest diameter. This instrument covers Ø75–88 mm, has carbide measuring faces and is designed for blind holes. The scale graduation is 0.001/0.005 mm, and the accuracy is ±0.005 mm. It is supplied in an aluminium case with the manufacturer’s test report.
Which Problems Does It Solve?
An ordinary two-point instrument requires you to rock it back and forth to find the right position. This causes variation between operators. Three contact points eliminate most of the tilt error and give a repeatable reading, even when you have repeated the measurement forty times in a shift. The carbide faces wear slowly, even with daily contact with hardened steel, so the instrument keeps its calibration for longer.
How It Is Used
You zero the instrument on a setting ring of nominal diameter. Then you guide the measuring head into the bore, turn until all three jaws make contact, and read off the diameter. If you measure at several depths, you can map taper. By measuring at different angles around the bore, you can also reveal ovality.
Three Concrete Situations
Hydraulics and pneumatics: When inspecting incoming cylinder tubes and when performing acceptance measurements on newly machined cylinders, a few hundredths of a millimetre decide whether the seal will hold.
Engine and compressor: During servicing, you need to know whether a cylinder bore is worn beyond tolerance before ordering new pistons or bushings. Here, a number with low uncertainty is decisive for the decision.
Calibration laboratory and quality department: The manufacturer’s test report provides a traceable starting point, and the instrument can be included in periodic checks against setting rings.
Why It Pays Off
The economics rarely lie in the price of the instrument itself. They lie in what is avoided: parts scrapped on a random number, rework of housings that were actually within tolerance, and discussions with subcontractors about who measured correctly. When two people get the same result without special training, you save time with every single inspection. This is especially true if the instrument is used daily.
You can see specifications and accessories for setting rings on the product page.