Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Deep holes are rarely round all the way down: how to map ovality and taper at 1000 mmThe cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Deep holes are rarely round all the way down: how to map ovality and taper at 1000 mmThe cleaning looked clean, but was the line gluten-free? How to get the answer in ten minutesSee the fault before you break up the floor: a 30-meter camera probe shows what is inside the pipeWhen the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep Up
Item number 17-813525

ETI TDS1 ppm conductivity meter. Measures ppm (parts per million). Resolution 10ppm, range 10-1990

824 DKK

In stock

TDS Conductivity Tester

  • Genuinely pocket-sized
  • Easy-to-read 6 mm LCD display
  • Indicates ppm (parts per million) or µS (micro-siemens)
  • Accuracy of ±2% of full scale
Documents:813 525 C of C
Request a quote 17-813525

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

These TDS conductivity meters provide the perfect solution for measuring ppm or μS. The TDS meters are ideal for monitoring a wide range of applications, including the amount of salts or dissolved solids in water. Readings are automatically temperature-compensated in the range of 0 to 50 °C.

There are two models of both TDS and conductivity meters, suitable for either low or high concentrations of total dissolved solids in liquids.

Conductivity Electrode Maintenance

The ETI range of conductivity meters includes TDS meters, nutrient meters, salt concentration meters, and WalkLAB Pro conductivity meters.

Various calibration solutions are available for regular calibration of the instruments.

Storage: It is best to store cells with the electrodes immersed in deionized water. All cells that have been stored dry should be soaked in distilled water for 5 to 10 minutes before use to ensure complete wetting of the electrodes.

The single most important requirement for accurate and reproducible results in conductivity measurement is a clean cell. A dirty cell will contaminate the solution and cause the conductivity to change. Grease, oil, fingerprints, and other contaminants on the sensing elements can cause erroneous measurements and sporadic reactions.

Electrodes can be cleaned with a mixture of 1 volume part isopropyl alcohol, 1 part ethyl ether, and 1 part HCl (1+1). After cleaning, rinse the cell thoroughly with water. If the old platinum black coating needs to be removed, it is often successful to apply aqua regia to the electrodes, or perform electrolysis in HCl. This should only be attempted by trained operators.

Electrodes can also be cleaned with detergents and/or nitric acid (1%) by dipping or filling the cell with the cleaning solution and stirring for two or three minutes.


Rinse the cell several times with distilled or deionized water and measure the cell constant before use.

Range: TDS1: 10-1990, TDS2: 100-9999, COND3: 10-1990, COND4: 100-19900
Resolution: TDS1: 10 ppm, TDS2: 100 ppm, COND3: 10µS, COND4: 100µS
Accuracy: ±2% of full scale
Battery: 4 x 1.5 volt LR44 button cell
Battery life: 100 hours
Display: 6 mm LCD
Dimensions: 15 x 32 x 147 mm
Weight: 70 grams
Packaging material: ABS plastic
Warranty: one year
Water/dust resistance: waterproof
Measurement scale: ppm (TDS1 & TDS2) or µS (COND3 & COND4)