Precision measurement of internal bore diameters is one of the classic metrology challenges in mechanical manufacturing. Two-point measuring instruments (internal calipers, internal micrometers, internal measuring arms) are inexpensive, but suffer from operator-dependent errors because the operator must manually rock the instrument to find the correct position. Three-point geometry solves the problem by making self-centering a built-in geometric property — but the three measuring arms require precision manufacturing of a mechanical mechanism, which places three-point instruments in the more expensive category. The TESA Imicro series has been the Swiss standard for three-point internal micrometers since the 1970s.
What the TESA Imicro ø25-30 mm is
TESA Imicro internal three-point micrometer of Holtest type, measuring range ø 25-30 mm (item 779.516) is a mechanical three-point internal micrometer from Swiss manufacturer TESA. The instrument:
- Has a measuring range of ø 25-30 mm (5 mm span).
- Has an accuracy of ±0.004 mm and a resolution of 0.001 mm.
- Uses three-jaw self-centering geometry via a threaded-cone mechanism.
- Has hardened-steel measuring surfaces for wear resistance.
- Has mechanical thimble reading — no batteries, no electronics.
- Is positioned as ECONOMY LINE — Swiss engineering at a reduced price.
- Pairs with separate TESA setting rings (779 series accessories) for zero calibration.
Basic specifications:
- Manufacturer: TESA (Switzerland)
- Series: Imicro ECONOMY LINE
- Type: Mechanical 3-point internal micrometer (Holtest type)
- Measuring range: ø 25-30 mm
- Accuracy: ±0.004 mm
- Resolution: 0.001 mm
- Measuring surfaces: Hardened steel
- Reading: Mechanical vernier on thimble
- Weight: approx. 250 g
- Item number: 64-779516
The geometric difference: two-point vs. three-point
A two-point internal measuring instrument (internal caliper, two-point internal micrometer) has two measuring surfaces that open within the bore. The measurement can only be correct if:
- The instrument is precisely perpendicular to the bore axis (not tilted).
- The instrument’s measuring axis passes precisely through the bore’s center (not offset).
- The operator has rocked the instrument back and forth and read the maximum value.
If any of these conditions is not met, the instrument reads a chord of the circle (less than the diameter). The consequence:
- 0.5° tilt → 0.004 mm error (on a 30 mm bore).
- 1° tilt → 0.015 mm error.
- 2° tilt → 0.060 mm error.
At tolerance class H7 (30 H7 = +0.021/0 mm), a 0.015 mm operator error already amounts to half the tolerance band — meaning good parts get rejected as defective, and bad parts get accepted as good.
Three-point geometry solves the problem: three measuring surfaces positioned 120° apart engage the bore wall simultaneously. The geometric consequence: the instrument centers itself in the bore. Operator angle error is automatically eliminated — the instrument finds the correct position independent of the operator.
The threaded-cone mechanism — why the Imicro is so precise
The Imicro system’s mechanism:
- Central measuring rod with an internal cone at the tip.
- Three measuring arms mounted 120° apart, with internal bevel surfaces against the cone.
- Precision thread on the rod, driven by the thimble.
- When the thimble is turned, the rod (and cone) advances more slowly.
- The cone pushes all three arms outward by an equal amount.
- The measuring surfaces on the arm ends engage the bore wall.
The precision comes from three sources:
- Thread quality: TESA’s threaded cone has micrometer-accurate pitch deviations (typically under 1 μm/mm).
- Cone geometry: The cone angle is precision-ground so the arms’ movement is linear with thimble rotation.
- Measuring surface grinding: The end surfaces on the three arms are spherically ground so contact with the bore wall is point contact (not line contact), which eliminates the influence of surface roughness.
Zero verification with setting rings
Three-point internal micrometers are zero-calibrated using precision-ground setting rings. A 30.000 mm setting ring has an internal diameter guaranteed within ±2 μm. Procedure:
- Clean setting ring on a clean measuring bench.
- Insert the instrument into the ring.
- Turn the thimble until the arms engage the ring wall with the correct measuring force.
- The reading should be 30.000 mm ±0.002 mm (a combination of instrument accuracy ±0.004 mm and ring accuracy ±2 μm).
- If the reading deviates, adjust the calibration screw or zero-point setting.
Recommended zero verification: daily before production starts, or after any impact/shock.
Where a three-point internal micrometer makes a real difference
Machined housing inspection: Engine block bores, gearbox bores, pump housing bores. H7, H8, H9 tolerances are standard, and three-point measurement is fast enough for production QC.
Hydraulic cylinder wear control: A worn hydraulic bore increases tolerance class and leakage. Annual maintenance inspection.
Bearing seat verification: Ball bearing seats must have the correct undersize for a press fit. Three-point measurement verifies that the machined housing is within tolerance.
Cylinder liner wear control: Combustion engines and compressors with replaceable liner sleeves. Three-point measurement at top, middle, and bottom positions reveals the wear profile.
Bushing inspection: After press-fitting, the internal diameter must be within tolerance for further machining.
Prototype and research manufacturing: External calibration lab verification of workpieces with controlled tolerances.
Calibration verification of two-point instruments: A three-point gauge is used as a reference to calibrate two-point internal calipers or micrometers.
Reverse engineering of existing parts: Accurate measurement of existing bore diameters for CAD modeling.
Repair verification: After repair grinding or build-up welding, the bore diameter must be verified to confirm correct restoration.
Supply chain quality audit: Incoming inspection of components delivered from an external supplier.
Practical handling
A few disciplined habits are needed to achieve the full accuracy:
- Clean measuring surfaces: Wipe both the instrument’s measuring surfaces and the bore wall with a clean cloth. Dirt = measurement error.
- Consistent measuring force: Turn the thimble slowly until you feel the built-in friction clutch (friction thimble). Consistent force = consistent readings.
- Temperature stability: The tool and the workpiece should be at the same temperature (20 °C ideal). Wait 5-10 minutes after handling.
- Avoid drops and impacts: The three-point mechanism is precise; a drop can ruin the accuracy. Store in the included case.
- Annual calibration: Even three-point instruments drift over time. Annual verification against a certified setting ring.
What you get for your money
TESA Imicro internal three-point micrometer 779.516, measuring range ø25-30 mm, accuracy ±0.004 mm, resolution 0.001 mm, hardened-steel measuring surfaces, mechanical thimble vernier reading, Swiss ECONOMY LINE precision engineering, three-jaw self-centering geometry via the threaded-cone-and-three-arm Imicro system.
DKK 5,865 is the instrument investment. Compared to a two-point internal micrometer (DKK 2,000-4,000, ±0.010 mm accuracy including operator error), the Imicro offers twice the accuracy and eliminates operator-rocking error. Compared to a digital three-point Mitutoyo Holtest (DKK 12,000-18,000, same accuracy but digital readout), the Imicro is about 40% cheaper, with the drawback that the reading requires vernier interpretation. For workshop QC and production inspection, it’s a proven standard.