Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Cold Room Fails Over the Weekend, the Alert on Your Phone Decides Whether the Goods Can Be SavedWhen temperature needs to be read in under half a second, self-inspection becomes a habit instead of a burdenWhen the Bore Is One and a Half Meters Deep, an Ordinary Bore Gauge Only Measures the EntranceLook inside the pipe instead of guessing: how a videoscope finds the fault without taking anything apartA thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator Uncertainty
Item number 28-DT400

Digital pocket thermometer with built-in stainless steel probe, °C or °F readings, max/min function and rubber protection, -20°C to +200°C. Waterproof and dishwasher safe for commercial dishwashers. BioCote® antimicrobial protection.

208 DKK

In stock

The DT400 pocket thermometer features a slim tip and a large digital display that is visible from the top of the instrument.

Request a quote 28-DT400

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Other models in the series 10

Description

The DT400 pocket thermometer with a thin probe features a large digital display visible from the top of the instrument. By using the max hold button, you can switch between the maximum reading and the current temperature reading.

The DT400 pocket thermometer can be used for checking food temperatures, and the thin PROBE provides a response within 6 seconds.

It is a waterproof thermometer and durable enough to be used for checking the final rinse cycle temperature in commercial dishwashers.

 

 


User Manual

Press the on/off button to start or stop the operation of the DT400. The unit automatically turns off after 35 minutes to save battery life. Press the ‘°F/°C’ button to select the Fahrenheit or Celsius scale.

MAX temperature:Press the “MAX” button to display the maximum recorded temperature. To clear the max reading from memory, press the MAX button and the on/off button simultaneously for 2 seconds to reset the unit to the current temperature display.

Data hold:To hold a displayed reading, press the “D-H” button. “D-H” is displayed in the upper right corner of the screen while the data hold function is active. Press the button again to return to normal operation.

Battery removal: Use a screwdriver blade or coin to turn the battery cover counterclockwise for removal. Replace the (AB13) (1.5V LR44) battery and turn the cover clockwise until it is tight.


Field Calibration Procedures

1. The DT400 is only calibratable in an ice slurry (60% crushed ice and 40% tap water) or a water bath. Do not attempt to calibrate in any other manner.

2. Immerse the thermometer stem to at least half its length in the ice slurry.

3. Wait until the reading becomes stable (typically ±2° of +32 °F or ±1° of 0 °C).

4. Press and hold the ‘D-H’ button for 8 seconds to initiate calibration.

5. ‘CAL’ is displayed in seconds, and calibration at 0 °C / +32 °F is complete.

6. Remove the thermometer from the ice water and continue measuring.

NOTE:“CAL” is displayed when the D-H key is pressed for 7 seconds, but the thermometer will not calibrate unless the probe is inserted into the ice.