Hoppa till innehåll
Free shipping over 3.000 DKK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometerVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometer

Allergen Testing for Crustaceans — A Clean Surface Is Just a Claim Until Someone Measures the Protein on It

Published 20 August 2026 at 16:54

Shrimp run on the line in the morning, and an allergen-free product runs in the afternoon. Between them lies a cleaning, a signature on the schedule, and a surface that looks clean. But “looks clean” is not a statement about protein. Allergen residues are invisible at the quantities that matter — a residue far too small to see can be more than enough to trigger a reaction in someone with a shellfish allergy. Cleaning is an action; verification is a measurement — and only the latter can be documented.

Allergen Lateral Flow Rapid Test EASY Kit for crustaceans, box of 10 tests and swab kit

What it is

A rapid test kit for detecting crustacean protein on surfaces and in rinse water — a lateral flow immunoassay that is read visually, much like a pregnancy test. The box contains 10 tests and a swab kit (ST-25), and requires no special equipment and no sample preparation. Analysis time is 10 minutes, and the detection limit is 0.5 ppm. The kit is stored at 2–8 °C and must not be frozen.

The procedure is a single step. For a swab sample: open the swab, squeeze off excess liquid, thoroughly wipe the designated surface, place the swab back in the bottle, close the cap and shake vigorously. The resulting solution is the test solution — invert the cap and add 200 µl, i.e. four drops, to the sample well on the test strip, which should lie flat. For a rinse water sample, the collected water is used directly as the test solution.

What problem it solves

Allergen control differs from microbiology in one crucial respect: heat treatment does not help. Bacteria can be killed, but an allergenic protein does not disappear from being heated — it has to be physically removed. That is why cleaning isn’t just hygiene in an allergen context; it is the control measure itself, and it is this that needs to be verified.

This is also where most self-inspection programs have their weakest link. Temperatures are measured, cleaning is ticked off. But the tick mark documents that someone carried out a procedure — not that the procedure worked. Hidden pockets in equipment, a cracked conveyor belt, a gasket or a hose can hold residues that a visual check will never catch. A test that reacts to the protein itself, down to 0.5 ppm, answers the question no routine can otherwise answer: is there anything left behind?

Getting the answer in 10 minutes is what makes the method usable in operation. A result from an external laboratory arrives days later, once production has long since run — it documents history. A rapid test is taken after cleaning and before the next run, while there is still something that can be done: clean again at the spot that showed a positive result, and test once more.

A limitation to bear in mind: the kit tests swabs and rinse water — not the food product itself. It is a tool for verifying cleaning between production runs, not for clearing a finished batch.

Three typical applications

  • Changeover between production runs: verifying cleaning between a crustacean-containing product and an allergen-free product — the classic cross-contamination scenario.
  • Validation of cleaning procedures: establishing whether the method actually works on the equipment in question, instead of assuming it does — particularly on new equipment or after a rebuild.
  • Commercial kitchens and catering: checking cutting boards, mixers, utensils and rinse water, where the same surfaces are used for many dishes throughout the day.

Why it pays off

The math here is not primarily about money. An allergic reaction in a guest or a consumer is a personal injury first and a business matter afterward — and afterward comes recall, regulatory action, press coverage and lost customer trust, in that order. The cost of ten tests is negligible compared to even the mildest of those outcomes.

There is also a purely operational economic side to this. Without a measurement, the cautious decision is always to clean longer, run more rinses, or separate equipment further — time that costs money every single time. With an objective answer, the procedure can be trimmed to what is actually needed, with the confidence that it’s enough. And should something go wrong, the difference between a company with documented allergen controls and one without is precisely what determines whether the matter can be contained.

Read more about the Allergen Lateral Flow Rapid Test EASY Kit for crustaceans →

More news

All news