Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometerVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometer

Your measurement is never better than the surface you measure against

Published 13 November 2026 at 01:53

Most people have experienced it: a height gauge shows two different values on the same workpiece, depending on where on the bench the measurement is taken. Or a measurement that was correct in the morning is off in the afternoon, when the workshop has warmed up. Before replacing the instrument, it is worth looking at what it is standing on.

Granitmåleplade, dimensioner 800x500x100 mm, vægt 136 kg, nøjagtighed ifølge DIN 876/1

What a granite surface plate is

It is a solid granite plate measuring 800 x 500 x 100 mm and weighing about 136 kg, with a lapped working surface that meets DIN 876/1. This is the inspection grade, where flatness is held within a few micrometers across the entire plate. It is so flat that gauge blocks can be wrung directly onto the surface, which makes the plate a primary length reference.

Why granite and not steel

There are three good reasons. Granite has a thermal expansion of about one third that of steel, so the plate changes far less when the room temperature fluctuates. It is non-magnetic and therefore does not pick up fields from clamping fixtures or magnetic stands. And it is self-indicating in the sense that when it is hit, a small chip forms instead of a burr that pushes material up. The damage is visible and measurable, rather than creeping in and distorting results.

When it is used

The plate is the reference floor for anything where a dimension must be read from a known surface. Typical uses are height measurement, checking gauge block stacks, squareness checks with a granite square, and serving as the datum for one-dimensional scanning measurements. It can sit on a dedicated granite stand or surface plate stand, so that it is stable in height and level.

Three situations from practice

In the toolroom, the workpiece is placed directly on the plate and the height gauge is zeroed against the surface. The difference between two measuring points is then real and not the result of a warped bench. In the quality department, the plate is used to check squareness on machined parts with a granite square, without the plate’s own form entering into the uncertainty. In an in-house calibration room, it is used to compare gauge blocks and setting standards, where an error of a few micrometers in the base would otherwise end up directly in the certificate.

The economics of a flat surface

The price is modest compared with what a faulty reference costs: scrapped parts, rework, complaints, and time spent looking for an error that was never in the instrument. Granite wears slowly and requires only cleaning and periodic inspection, so the plate typically serves for many years. When all other instruments on the bench are measured against the same surface, measurements are also easier to compare between people and shifts.

Next step

If your measurements today rest on an ordinary workshop bench or a plate of unknown condition, this is where you get the most precision for your money. See data and specifications on the product page.