Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%A thermometer reading 72 °C could be several degrees off: how to check it in a few minutesWhen temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trust
Item number 79-2500018-001

Allergen Lateral Flow Rapid Test EASY Kit: Peanut Allergen Test for 10 determinations, 38221900, Japan

1.195 DKK

In stock
  • Simple and easy to use
  • Specialized for swab and rinse water samples
  • No special equipment required
  • Simple sample preparation
  • Low detection limit: 0.5 ppm
Request a quote 79-2500018-001

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

79-2500018-001 Test allergens > Rapid Test

The Allergen Lateral Flow Rapid Test EASY Kit is designed for the rapid detection of protein from allergenic ingredients on environmental surfaces (swab tests) and rinse water samples. It is a qualitative test in lateral flow immunoassay format for visual detection.
The test procedure is very simple and is performed in only 1 step. The kit is supplied with a swab kit (ST-25) and requires no additional consumables for testing.
This kit cannot test food materials, but is a one-step test method for test strips and rinse water. No other test kit on the market has a procedure as simple as Rapid Test Easy.

1 x box with 10 tests


Analysis time: 10 min, no sample preparation time required
Storage: 2−8˚ C (35−46˚ F), DO NOT FREEZE


For swab test samples
Open a screw cap on the cotton swab and squeeze the cotton swab to remove excess moisture.
Wipe the specified surface thoroughly with the swab.
Place the swab in the bottle, secure the cap properly, and shake vigorously. The resulting solution is called the test solution.
Place a test strip horizontally. Turn the cap upside down and add 200 μL (4 drops) of test solution to the sample application well by squeezing.
NOTE: Determine the appropriate amount of PBS before testing. Commercially available swab test kits containing PBS are acceptable. Ensure to check the kit for ingredients such as peptone in advance.
For rinse water samples
Collect the water, which is designated as the test solution.
Place a test strip horizontally and add 200 μL of test solution to the sample application site.
Analysis
Incubate for 10 minutes at room temperature.
Read the results from the test window.
Results: A) Positive: A red-purple line in the test window together with red color in the control window. B) Negative: No line in the test window together with red color in the control window. C) Invalid: No color in the control window.
NOTE: If there is no color in the control window, repeat the test with a new swab. Negative results will occur if the test solution contains target protein at levels below the limit of detection. False negative results may occur if the test solution contains target protein at relatively high concentrations; in such cases, repeat the test with a diluted test solution.