Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When temperatures are written down by hand, the measurement itself is rarely the weak linkWhen the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure against
Item number 77-1000101

Coliform test strips 25 per pack 38210000, UK

937 DKK

In stock
  • Easy to use
  • Clear color change from purple to yellow
  • No additional reagents required
  • Detection limit 1 cfu/cm²
  • Storage at room temperature
Request a quote 77-1000101

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

77-1000101 Test hygiene > Test swabs for bacteria

Escherichia coli and Coliforms are traditionally used as indicator organisms for fecal contamination in water and other environmental samples. The detection of these organisms typically indicates poor hygiene. Coliform Isolation Transwab® (MW503) provides a simple method for detecting these organisms.
This test consists of a cotton swab for sample collection and a tube containing indicator medium, packaged together in a convenient pouch that can be stored at ambient temperature.
Coliform swabs show a distinct color change from purple to yellow when coliform bacteria are present. The test is completely self-contained and requires only a means to incubate the swab at 37 °C. 


Measurement time:
Incubation time: 18-24 hours at 37ºC
Test time: 2-5 minutes
Shelf life: 12 months
Storage: +5 to +25° C
Swab length: 15 cm


1. Peel off the cover to expose both caps.
2. Remove the swab and the test site.
3. Remove the cap from the culture tube with your thumb and index finger and discard it.
4. Insert the swab into the culture tube and push it down completely to fully immerse the swab.
5. Fill in location details, etc.
6. Incubate at 37ºC for 18-24 hours.
7. Read the result. A positive result is indicated by a color change from purple to yellow. A negative result shows no color change.
8. Discard the tube.

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *