Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometerVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometer
Item number 53-PQ3350-3

Power Quality Meter with 3000A Clamp Meter with Cord

Call for price

In stock

Complete with 3000A 18 “flexible current clamp probes

Request a quote 53-PQ3350-3

Category:

Description
  • Data logging of single-phase and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single-phase readings or 17,476 three-phase readings)
  • Flexible clamp probes can be used to wrap around busbars and wire bundles
  • Large backlit LCD screens displaying up to 35 parameters on one screen
  • Clamp-on True RMS measurement with on-screen Harmonics display
  • Simultaneous display of harmonics and waveform
  • Waveform display with Peak values (1024 samples / period)
  • Analysis of total harmonic distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT (1 to 600) and VT ratio (1 to 3000)
  • Graphic Phase diagram with 3-phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and unbalance factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and interruptions) with programmable threshold (%)
  • Optically isolated USB interface with software to download waveforms, Current Parameters and harmonics
  • Includes 3 flexible current clamps, 4 lead voltage with crocodile clips and retractable clip probes, 8 AA batteries, Universal AC adapter, software, USB cable and case
Specification
  • Data logging of single-phase and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single-phase readings or 17,476 three-phase readings)
  • Flexible clamp probes can be used to wrap around busbars and wire bundles
  • Large backlit LCD screens displaying up to 35 parameters on one screen
  • Clamp-on True RMS measurement with on-screen Harmonics display
  • Simultaneous display of harmonics and waveform
  • Waveform display with Peak values (1024 samples / period)
  • Analysis of total harmonic distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT (1 to 600) and VT ratio (1 to 3000)
  • Graphic Phase diagram with 3-phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and unbalance factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and interruptions) with programmable threshold (%)
  • Optically isolated USB interface with software to download waveforms, Current Parameters and harmonics
  • Includes 3 flexible current clamps, 4 lead voltage with crocodile clips and retractable clip probes, 8 AA batteries, Universal AC adapter, software, USB cable and case