Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometerWhen Cold Chain Temperatures Must Be Documented, a Room Thermometer Is Not EnoughVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Core product temperature can be documented even when nobody is watching the thermometerWhen Cold Chain Temperatures Must Be Documented, a Room Thermometer Is Not Enough
Item number 53-AN200-NIST

Anemometer with IR thermometer, with traceable calibration certificate

6.093 DKK

In stock

Anemometer, CFM, with traceable calibration certificate

Request a quote 53-AN200-NIST

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: , , ,

Description
  • Anemometer with built-in non-contact IR thermometer measures surface temperatures up to 260 °C with a Distance:Spot ratio of 8:1, featuring a laser pointer to identify the measurement target
  • Simultaneous display of air flow or air velocity along with ambient temperature
  • Easy to set the measurement range; cm 2 values are stored in the meter’s internal memory for the next measurement
  • Resolution down to 0.01 m/s
  • 20-point averaging for air flow
  • Large (9999 Count) LCD display, backlit
  • 3% accuracy in air velocity measurement thanks to a low-friction 72mm ball-bearing impeller with a 120cm connection cable
  • Complete with impeller sensor with 120cm cable, 9V battery, and protective rubber case
  • Lead time is 5 weeks for a NIST certificate
Specification
  • Anemometer with built-in non-contact IR thermometer measures surface temperatures up to 260 °C with a Distance:Spot ratio of 8:1, featuring a laser pointer to identify the measurement target
  • Simultaneous display of air flow or air velocity along with ambient temperature
  • Easy to set the measurement range; cm 2 values are stored in the meter’s internal memory for the next measurement
  • Resolution down to 0.01 m/s
  • 20-point averaging for air flow
  • Large (9999 Count) LCD display, backlit
  • 3% accuracy in air velocity measurement thanks to a low-friction 72mm ball-bearing impeller with a 120cm connection cable
  • Complete with impeller sensor with 120cm cable, 9V battery, and protective rubber case
  • Lead time is 5 weeks for a NIST certificate
PDF (7)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *