Published July 10, 2026 at 09:56
You’ve just mounted a 600 mm slide rail on a milling machine, and the operator reports that workpieces come out with 0.03 mm of skew across the full length. The skew comes from somewhere. It could be the machine. It could be the straightness of the slide rail. It could be the flatness of the worktable. You can’t test the hypothesis “the machine is off” against the hypothesis “the worktable is off” without a reference edge you KNOW is straight. That’s the role a Class 0 triangular straightedge fills: a standardized, craft-made reference edge that is straight to a known tolerance.
DIN 874/876: the standard behind the class number
The straightedge standard series is DIN 874 (for prism-shaped straightedges) and DIN 876 (for triangular straightedges). These standards define class tolerance levels:
- Class 00: Straightness deviation under ±(2 + L/250) μm, where L is the length in mm. At 750 mm that gives ±5 μm.
- Class 0: Straightness deviation under ±(4 + L/125) μm. At 750 mm that gives ±10 μm.
- Class 1: Straightness deviation under ±(8 + L/62.5) μm. At 750 mm that gives ±20 μm.
- Class 2: Straightness deviation under ±(16 + L/32) μm. At 750 mm that gives ±40 μm.
The formula accounts for the fact that long straightedges are harder to manufacture to a tight relative tolerance. A 250 mm Class 0 straightedge must be within ±6 μm; a 1500 mm Class 0 straightedge must be within ±16 μm. That’s still impressive — 16 μm is the thickness of a human hair spread over 1500 mm.
Why cast iron and not steel?
Class 0 straightedges are classically made from special fine-grained cast iron (pearlitic grey cast iron with a grain size of 0.05-0.1 mm). Why not steel, which is otherwise harder and more robust?
The reason lies in dimensional stability over time. A steel workpiece contains residual stresses from rolling, hardening and machining. These stresses relax over 5-20 years and cause dimensional drift of 10-50 μm on a 750 mm piece. A Class 0 straightedge that drifts 10 μm is no longer Class 0.
Cast iron is different. Once the workpiece has been:
- Rough-cast to shape.
- Aged (natural stress relief for 6-12 months at room temperature, or artificial aging at 500-600 °C for 8-12 hours).
- Rough-machined.
- Aged again.
- Fine-machined.
- Hand-scraped.
…residual stresses are below 10 MPa, and dimensional drift over 50 years is below 5 μm. This makes cast iron the preferred reference artifact material in metrology. Support surfaces on coordinate measuring machines are likewise made of cast iron or granite (even more stable, but more expensive).
Hand-scraping: the traditional craft
The central step in manufacturing a Class 0 straightedge is hand-scraping. This is still manual work — no CNC process can match it:
- The workpiece is rough-machined to within ±20 μm of nominal shape.
- A reference surface (a matching Class K cast-iron plate) is thinned with scraping ink (typically red lead marker on a blue background).
- The straightedge workpiece is placed on the reference plate. High spots on the workpiece pick up the scraping ink.
- Using a scraping tool (traditionally a hardened steel scraper with a small circular or oval blade), the craftsman scrapes small flag-shaped depressions into the high spots.
- The workpiece is placed back on the reference plate. New high spots appear.
- The cycle is repeated 20-100 times until the scraped depressions are evenly distributed across the entire surface with 8-12 spots per cm².
This process is called “spot-scraping” or “flag-scraping” in English, “Schaben” in German. It takes 8-30 hours for a 750 mm straightedge and is performed only by trained craftsmen. Even today, with all modern CNC technology, hand-scraping is the only known method for achieving Class 00 and Class 0 flatness on cast iron.
The side effect of hand-scraping isn’t just flatness. The small scraped depressions also act as oil pockets: a thin oil film between the straightedge and another surface collects in the depressions and reduces wear during movement between the surfaces.
Triangular 45° shape: why not just a flat bar?
The straightedge has a 45° triangular cross-section — not a flat rectangular bar. There are technical reasons for this choice:
- Stiffness-to-weight ratio: A 45° triangular profile has higher resistance to bending than a flat bar of the same weight. Over a 750 mm length, this means the straightedge doesn’t sag under its own weight when resting on supports.
- Two scraped surfaces + one fine-machined edge: The 45° shape gives two broad-side faces (which can be scraped to flatness) and one narrow-side edge. The edge between the two scraped sides is the precise reference line you use for the light-gap method or with a feeler gauge.
- Ergonomic handling: The straightedge can be lifted or set down without touching the precise edge.
Classic sizes for triangular Class 0 straightedges: 500 mm, 750 mm, 1000 mm and 1500 mm. Longer straightedges (2-3 m) also exist but are rare and expensive — at 2 m, the Class 0 tolerance is ±20 μm, and manufacturing requires 40-60 hours of scraping.
Measurement methods with a straightedge
There are three standard methods for using a straightedge to measure the straightness of another surface:
1. Light-gap method: The straightedge is laid with its fine-machined edge on the surface to be measured. A strong light source is placed behind the setup. The operator looks under the edge. If no light gap is visible, the gap is under 5 μm (the human eye can just barely detect a 5 μm light gap). If a yellowish light gap appears, the gap is 5-20 μm. If a reddish light gap appears, the gap is over 20 μm.
This method is fast and requires no accessories — but it’s qualitative (not digital) and operator-dependent.
2. Feeler gauge method: Feeler gauges are thin steel blades of known thicknesses (0.02 mm, 0.03 mm, 0.05 mm, etc.). The straightedge is laid on the surface, and the operator tries to insert feeler blades into any gaps. The thickest blade that fits gives the gap size.
This method is quantitative but discrete — you can only measure with the feeler blades available. Thicknesses of 0.02 mm, 0.03 mm, 0.05 mm, 0.10 mm, etc. limit the resolution.
3. Dial indicator on a stand: The straightedge is laid on the surface. A dial indicator (resolution 0.001 mm) is mounted on a magnetic or vacuum stand and positioned so the measuring tip contacts the top edge of the straightedge. The stand is then drawn along the length of the straightedge, and the dial indicator shows deviations in the surface height.
This method provides the most precise and reproducible measurement. Standard practice in qualified metrology labs.
Applications for Class 0
Surface plate calibration: Checking granite and cast-iron reference plates after installation or after transport. The straightedge shows whether the plate has been mounted out of true or has worn.
Machine bed flatness verification: Milling machines, lathes and grinding machines have worktables that must be flat within 20-50 μm over their full length. The straightedge is the standard QC tool.
Straightedge production QC: The straightedge is used to calibrate Class 1 and Class 2 straightedges (the “K/00/0 verification cascade”).
Calibration lab work: For ISO 17025-accredited work, Class 0 is the minimum required class.
Precision assembly of large workpieces: Shipbuilding, aerospace components, railway bogie assembly — anywhere long, continuous straight surfaces are critical.
When Class 1 or Class 2 is enough
Not every application requires Class 0. Consider Class 1 (±20 μm at 750 mm) if:
- You’re calibrating general tools with tolerances of 0.1 mm or wider.
- Workpieces are over 500 mm but the tolerance requirement is 0.05 mm.
- The straightedge is used as a workshop standard, not a calibration lab standard.
Class 2 (±40 μm at 750 mm) is sufficient for rough production QC, educational purposes, and hobby workshops. Class 0 and Class 00 are professional tools that only pay off in serious metrology.
Maintenance and calibration cycle
A Class 0 straightedge is relatively low-maintenance but requires:
- Proper storage: Protective case with foam lining. Never in loose contact with other cast-iron tools.
- Rust prevention: After use, wipe the straightedge with an oil-impregnated cloth. Store dry.
- No contact with hand sweat: Cotton gloves are recommended when handling. The chloride content in hand sweat causes pitting corrosion over time.
- Periodic calibration: Every 12 months for shop-floor use; every 6 months for calibration lab use. Send back to an accredited calibration lab (e.g. TÜV, DAkkS or a national metrology institute).
Calibration cost: DKK 800-2,500 per straightedge per calibration, depending on class and length.
What you get for the money
Triangular straightedge 45° Class 0 to DIN 876/0, length 750 mm, cross-section approx. 90 mm × 90 mm × ~40 mm height, made of special fine-grained cast iron with two artificial stress-relief stages, both broad sides hand-scraped with even spot distribution (8-12 spots per cm²), fine-machined reference edge between the scraped sides, straightness tolerance ±10 μm over the full 750 mm length per the DIN 876 Class 0 formula, includes calibration documentation verifying the straightness deviation over the full length. DKK 6,058.
For workshop metrology where you need to verify straightness on worktables, slide rails and long workpieces with requirements of 0.02-0.05 mm, this instrument is the logical choice. For hobby use or rough production QC, Class 1 or Class 2 is sufficient and cheaper.
Read more: Triangular straightedge 45° Class 0, 750 mm in the shop →