Two datasheets lie side by side. One promises an accuracy of a few micrometres, the other mentions accuracy almost in passing, but states a repeatability of 0.05 µm. The intuitive conclusion is that the first instrument is better. For the type of measurement probes are used for, that conclusion is often wrong — and the difference is worth understanding before you choose.
What it is
TESA GT61 is an analog position probe — a measuring probe mounted in a fixture, a measuring column, or a built-in inspection station, that outputs an electrical signal instead of a reading on a scale.
- Measuring range ±5 mm
- Repeatability 0.05 µm, accuracy (1+4L) µm
- Measuring force 0.9 N, spring-forward probe movement
- Sensitivity 29.5 mV/V/mm — the signal is ratiometric and requires a matching amplifier or display unit
- IP65, axial cable outlet
- Dimensions A/B/C 29.5/81/120 mm
- Hardened and ground reference surfaces
The problem it solves
A probe rarely measures an absolute dimension — it measures a difference. The fixture is zeroed against a setting piece or a master, and each workpiece is then read as a deviation from that. This is precisely why linearity error plays a minor role: it is essentially the same right around the zero point for both the master and the workpiece, and cancels itself out of the equation. What remains as actual measurement uncertainty is the spread from one measurement to the next — in other words, the repeatability. A probe with 0.05 µm repeatability can therefore distinguish between workpieces that an instrument with a nicer-looking accuracy figure, but poorer spread, cannot.
The constant measuring force is the other half of the story. On a handheld micrometer, the operator’s hand determines how hard the measuring faces are pressed against the workpiece, and on soft or thin-walled workpieces this shifts the reading more than the tolerance band itself. A spring-loaded probe with 0.9 N applies the same force every single time, regardless of who places the workpiece in the fixture. That removes the single biggest source of difference between two operators.
IP65 and axial cable outlet are about where the measurement can take place. Sealing against coolant, chips and dust means inspection can happen right at the machine instead of in a measuring room — and the axial cable outlet makes it possible to place several probes close together in the same fixture, where a side-mounted cable would collide with its neighbour.
Three typical applications
- Multi-probe fixture: several dimensions on the same workpiece are read simultaneously when the part is placed in the fixture — seconds instead of a measurement protocol per workpiece.
- Inspection at the machine: setup checks and ongoing spot checks in the production cell, where coolant rules out an unprotected instrument.
- Measuring column and laboratory work: comparative measurement against a master for incoming inspection and reference work.
Why it pays off
Measurement uncertainty costs in two ways at once. Workpieces within tolerance are rejected because the measurement’s spread is added on top of the tolerance band as a safety margin — and workpieces outside tolerance slip through for the same reason. The smaller the spread in the measurement, the narrower that margin can be made, and the closer you get to rejecting precisely what is actually wrong.
Then there’s time. A fixture where the workpiece is placed and read costs a few seconds per part. A manual measurement with a handheld instrument costs both more time and an operator’s attention — and that is usually what determines whether the check is carried out every time or only when someone has time.