Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustThe pipe wall looks intact from the outside, but how much steel is left inside?

A Hole Isn’t Properly Measured Until the Instrument Sits Centered Without the Operator’s Help

Published 12 October 2026 at 16:45

Two skilled operators measure the same hydraulic cylinder and get two different figures. The difference is often not in the dial gauge itself, but in how the instrument was held in the hole. If it tilts a few degrees, or sits slightly off-center, the diameter reading is wrong, and the hole is either wrongly approved or wrongly rejected.

Kroeplin internal measuring instrument Intertest type H240, 40-60 mm

What is the Intertest H240

The Kroeplin Intertest H240 is an internal measuring instrument for holes in the range of 40-60 mm. The instrument has three measuring jaws placed 120° apart, which open and close via a precision mechanism. The jaws center themselves in the hole, and the dial gauge is built into the instrument body, so no separate indicator needs to be mounted. Graduation is 0.01 mm, accuracy is ±0.03 mm, and repeatability is 0.01 mm.

What problem does it solve

With a two-point measuring tool, centering is left to the operator. This takes practice and time, and the result varies from person to person. Here, the jaw geometry takes care of the centering, while the operator guides the head into the hole and reads the deviation directly. The instrument is zeroed against a setting ring, after which you can see how much the hole deviates from the nominal size. The adjustable tolerance markers make it possible to see at a glance whether the hole is within limits.

Where and when is it used

The instrument is intended for situations where many holes must be checked quickly, and where the deviation matters more than the absolute diameter. The housing is shock- and impact-resistant and dustproof (IP65), so it can stay at the machine and not just on the quality department’s bench.

    Hydraulics and pneumatics. When inspecting cylinder bores for acceptance, you want the same result regardless of who is measuring. This provides a common basis between production and quality.

    Machined housings. After boring or reaming, the hole is checked at the machine before the workpiece is removed from the fixture. Errors are caught while they are still cheap to correct.

    Maintenance. When bushings wear, you can measure how far the hole has moved from the nominal size, and thus assess whether the part can stay in place or needs to be replaced. Measurements can be compared from one time to the next.

    Why it pays off

    The gain lies in three things. Measuring is faster, because the operator doesn’t have to search for the maximum reading by rocking the instrument. Fewer workpieces are scrapped or approved by mistake, and that is rarely small change when the workpiece has already been through several operations. Finally, several employees can measure in the same way, so you don’t depend on one experienced person. The instrument is supplied with a measurement report, which makes it easier to fit into a calibration and inspection routine.

    If you regularly have holes in the 40-60 mm range where the tolerance is measured in hundredths, the H240 is worth a closer look.