Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground Stakes

Probing isn’t two measurements, but one measurement that doesn’t care where the workpiece lies

Published 26 August 2026 at 00:29

A measuring probe emits an electrical signal, not a number. It therefore needs a unit that powers it, converts the signal, and displays the result. That sounds like an accessory, but it’s in this unit that the actual measurement is defined — and the most interesting function on it is one that looks like simple arithmetic: ±A±B.

Tesatronic TWIN-T20 displayenhed med 7 tommer touchskaerm og to sondeindgange

What it is

Tesatronic TWIN-T20 — a display unit for TESA measuring probes and instruments.

  • Two inputs for half-bridge probes plus two USB-A for TESA instruments, two readings simultaneously
  • Combination function ±A±B
  • Resolution 0.1 µm, eight comparator ranges from ±5000 down to ±5 µm plus auto
  • Static and dynamic measurements, 4300 samples per second, with min, max, max-min and average value memory
  • Tolerance indication, 7-inch touchscreen
  • RS232 and TESA BUS, USB-B as HID keyboard, connection for Bluetooth transmitters
  • DIN rail, IP65 front, 190 x 112 x 119 mm, calibration protocol included

Why two probes change the measurement

Place two probes facing each other with the workpiece in between, and read the sum. If the workpiece shifts slightly upward, the upper probe is pressed in by exactly as much as the lower one is allowed to extend. The sum doesn’t change. The result is a thickness measurement that is completely indifferent to where in the gap the workpiece sits.

This is a bigger deal than it sounds. With a single probe, the workpiece has to rest against a fixed surface, and every trace of dirt, every irregularity and every operator’s way of placing the workpiece feeds directly into the measurement. With two probes and a sum, that whole problem disappears — the workpiece’s position is no longer a source of error.

And if you subtract one from the other instead, you measure the difference. Two probes at each end of a surface give you parallelism. Two probes on either side of a shaft give you runout. Same two probes, same setup — only the sign changes.

Static and dynamic are two different questions

4300 measurements per second isn’t there to show a number faster. It’s there so you can set the workpiece in motion and capture what happens along the way. Turn a shaft under the probe and let the unit hold on to max and min, and the difference between them reveals runout — a property that doesn’t exist in a single reading at all.

Static measurement answers “how big”. Dynamic measurement answers “how round”, “how flat” and “how much does it wander”. That’s why the memory has exactly max, min, max-min and average: each of them corresponds to a property you’d actually write into a specification.

Two practical details

Eight comparator ranges from ±5000 to ±5 µm mean the display can be scaled so the tolerance band fills the entire scale. Then the reading is no longer a number you have to judge, but a position you can see — the same idea as tolerance markings on a dial indicator, just electronic.

USB-B as HID keyboard is the most underrated function on the whole unit. The instrument presents itself to the computer as a keyboard and simply types the measured value in wherever the cursor is. No driver, no integration, no special program — the measured value lands in the spreadsheet or the log without anyone typing it, and therefore without typing errors.

Three typical applications

  • Fixed inspection stations: thickness and parallelism on series of workpieces.
  • Runout and roundness: dynamic measurement on rotating workpieces.
  • Documented inspection: where the values need to go straight into a spreadsheet without manual entry.

Why it pays off

A probe is a good sensor, but it only becomes a measurement once someone has decided what should be calculated from the signal. That decision is what this unit embodies — and it’s often the difference between a setup that requires an experienced operator and one where the workpiece is simply placed in.

That’s the real gain: a measurement that doesn’t depend on how the workpiece is placed gives the same answer no matter who performs it. And a measurement everyone agrees on is the only kind that can be used to make decisions.

Read more about the Tesatronic TWIN-T20 display unit →

More news

All news