Hoppa till innehåll
Free shipping over 3.738 DKK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can Trust
Item number 82-1999

Measuring Loupe, Peak Lupe 1999. Magnification 7x

1.673 DKK

In stock
Request a quote 82-1999

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Other models in the series 8

Description

82-1999 Magnifying Glasses & Loupes > Loupes with measuring capability

The optical system used in this loupe is not conventional, but rather “telecentric,” which means that a small aperture at the focal point of the lens system allows for the measurement of three-dimensional objects such as spheres and cylinders, in addition to the length and width of flat objects, without parallax error. The telecentric Peak Loupe measuring loupe 1999 is essentially equivalent to an expensive profile projector. The lens system, consisting of three elements in two groups, has been specifically developed for these purposes.

Magnification 7 x
Focusable Yes
Field of view 20 mm.
Working distance 20 mm.
Scale 0.1 mm.
Optical properties Telecentric,
distortion-free
Size 38 x 74 mm
Weight 73 grams
Packaging Included
Standard scale Included as standard

 

To use this loupe, the distance between the scale and the lens system must first be adjusted by turning a knurled outer tube until the scale is clearly visible through the aperture with the largest diameter (3 mm), which can be adjusted using the rotating ring on the tip of the loupe. Then, place the loupe on the object to be measured so that the measuring scale is in contact with it, and read the length on the scale. This scale is divided into increments of 0.1 mm over a length of 20 mm, allowing the length of an object to be read with an error of less than 0.03 mm. When measuring three-dimensional objects, the aperture should be set to the smallest diameter (1 mm) or, preferably, use one with a 0.5 mm wide slit. The slit should be perpendicular to the line whose length is to be measured. Even in this case, parts of the object not in contact with the scale may appear blurred because they are not perfectly focused. No errors will occur when measuring length as long as the center distance between the unfocused images is measured, since the reduced brightness in the images resulting from the small aperture is compensated by the higher illumination of the object, which is a characteristic of the telecentric system.

 

Additional information
Product type

Measuring scale

Magnification range

Specification

82-1999 Magnifying Glasses & Loupes > Loupes with measuring capability

The optical system used in this loupe is not conventional, but rather “telecentric,” which means that a small aperture at the focal point of the lens system allows for the measurement of three-dimensional objects such as spheres and cylinders, in addition to the length and width of flat objects, without parallax error. The telecentric Peak Loupe measuring loupe 1999 is essentially equivalent to an expensive profile projector. The lens system, consisting of three elements in two groups, has been specifically developed for these purposes.

Magnification 7 x
Focusable Yes
Field of view 20 mm.
Working distance 20 mm.
Scale 0.1 mm.
Optical properties Telecentric,
distortion-free
Size 38 x 74 mm
Weight 73 grams
Packaging Included
Standard scale Included as standard

 

To use this loupe, the distance between the scale and the lens system must first be adjusted by turning a knurled outer tube until the scale is clearly visible through the aperture with the largest diameter (3 mm), which can be adjusted using the rotating ring on the tip of the loupe. Then, place the loupe on the object to be measured so that the measuring scale is in contact with it, and read the length on the scale. This scale is divided into increments of 0.1 mm over a length of 20 mm, allowing the length of an object to be read with an error of less than 0.03 mm. When measuring three-dimensional objects, the aperture should be set to the smallest diameter (1 mm) or, preferably, use one with a 0.5 mm wide slit. The slit should be perpendicular to the line whose length is to be measured. Even in this case, parts of the object not in contact with the scale may appear blurred because they are not perfectly focused. No errors will occur when measuring length as long as the center distance between the unfocused images is measured, since the reduced brightness in the images resulting from the small aperture is compensated by the higher illumination of the object, which is a characteristic of the telecentric system.

 

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *