Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the Hole Is 500 mm Deep, the Measuring Instrument Has to Keep UpSee why the drain is blocked before you tear up the floor: a camera on five meters of cableWhen two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground Stakes
Item number 17-813525

ETI TDS1 ppm conductivity meter. Measures ppm (parts per million). Resolution 10ppm, range 10-1990

824 DKK

In stock

TDS Conductivity Tester

  • Genuinely pocket-sized
  • Easy-to-read 6 mm LCD display
  • Indicates ppm (parts per million) or µS (micro-siemens)
  • Accuracy of ±2% of full scale
Documents:813 525 C of C
Request a quote 17-813525

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

These TDS conductivity meters provide the perfect solution for measuring ppm or μS. The TDS meters are ideal for monitoring a wide range of applications, including the amount of salts or dissolved solids in water. Readings are automatically temperature-compensated in the range of 0 to 50 °C.

There are two models of both TDS and conductivity meters, suitable for either low or high concentrations of total dissolved solids in liquids.

Conductivity Electrode Maintenance

The ETI range of conductivity meters includes TDS meters, nutrient meters, salt concentration meters, and WalkLAB Pro conductivity meters.

Various calibration solutions are available for regular calibration of the instruments.

Storage: It is best to store cells with the electrodes immersed in deionized water. All cells that have been stored dry should be soaked in distilled water for 5 to 10 minutes before use to ensure complete wetting of the electrodes.

The single most important requirement for accurate and reproducible results in conductivity measurement is a clean cell. A dirty cell will contaminate the solution and cause the conductivity to change. Grease, oil, fingerprints, and other contaminants on the sensing elements can cause erroneous measurements and sporadic reactions.

Electrodes can be cleaned with a mixture of 1 volume part isopropyl alcohol, 1 part ethyl ether, and 1 part HCl (1+1). After cleaning, rinse the cell thoroughly with water. If the old platinum black coating needs to be removed, it is often successful to apply aqua regia to the electrodes, or perform electrolysis in HCl. This should only be attempted by trained operators.

Electrodes can also be cleaned with detergents and/or nitric acid (1%) by dipping or filling the cell with the cleaning solution and stirring for two or three minutes.


Rinse the cell several times with distilled or deionized water and measure the cell constant before use.

Range: TDS1: 10-1990, TDS2: 100-9999, COND3: 10-1990, COND4: 100-19900
Resolution: TDS1: 10 ppm, TDS2: 100 ppm, COND3: 10µS, COND4: 100µS
Accuracy: ±2% of full scale
Battery: 4 x 1.5 volt LR44 button cell
Battery life: 100 hours
Display: 6 mm LCD
Dimensions: 15 x 32 x 147 mm
Weight: 70 grams
Packaging material: ABS plastic
Warranty: one year
Water/dust resistance: waterproof
Measurement scale: ppm (TDS1 & TDS2) or µS (COND3 & COND4)