Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can TrustVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When two hands measure the same bore differently: How three measuring points eliminate operator errorWhen the Bore Has to Be Measured Right: How a Self-Centering Three-Point Micrometer Removes Operator UncertaintyThree measuring points give a bore diameter that doesn’t depend on who is measuringWhen the multimeter shows 90 volts on a disconnected cable: how to tell ghost voltage from the real thingRead the tolerance in seconds when the micrometer shows the deviation directlySmall holes are rarely measured correctly with two points: how three contact points give you a diameter result you can trustYour measurement is never better than the surface you measure againstHow to Measure Ground Resistance Without Disconnecting the Ground Connection and Without Ground StakesSurface temperature reads incorrectly if the emissivity doesn’t match the materialWhen the Bore Looks Round but the Measurement Still Misleads: How Three Contact Points Give You a Number You Can Trust
Item number 28-KM400AP

Allergen-safe digital pocket thermometer, measuring range -50°C to +200°C

247 DKK

In stock

The KM400AP waterproof allergy thermometer is color-coded for food allergen procedures and features a thin tip for fast response times.

Request a quote 28-KM400AP

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Other models in the series 14

Description

The KM400AP waterproof allergen thermometer is color-coded for food allergen procedures and features a thin probe for fast response times.

The pen-style KM400AP Waterproof Allergen Thermometer is purple, the agreed-upon color in the food service industry for kitchens to identify allergen-free foods.

If your kitchen regularly handles milk, eggs, fish, peanuts, tree nuts (walnuts, almonds), wheat, soybeans, and shellfish (shrimp, crab) or other food allergens, preventing cross-contamination becomes increasingly important. HACCP plans now include detailed regulations regarding the segregation of foods or ingredients that may cause allergies and the use of separate utensils for different foods.

The KM400AP waterproof allergen thermometer features a 1.5 mm thin probe for a fast response, along with a hold function on the thermometer that allows the user to temporarily fix the reading on the screen while noting a measurement.

Features:

  • Automatic shut-off
  • Data hold
  • BioCote antimicrobial protection
  • NSF listed
  • Color-coded for food safety
  • Purple color is for allergens
  • Thin probe for fast response
  • Easy-to-read LCD display
  • On/off button
  • 2.75 inch (75 mm) stainless steel shaft
  • Storage case with clip
  • 1.5 volt battery included

 


User Manual

Press the ”ON/OFF” button to start or stop the operation of the KM400AP. The unit automatically turns off after 35 minutes to conserve battery life. A low battery is indicated by ”LOB” flashing alternately with a reading. Replace the (AB13) (1.5V LR44) battery immediately.


Switching between °C and °F

With the unit turned off, press and hold the ”ON/OFF” button, and the display will switch between “°F” and “°C”. Release the ”ON/OFF‘ button when the desired mode is displayed.


Data Hold Function

To hold a displayed reading, press the ”D-H” (Data Hold) button. The reading flashes when Data Hold is active. Press the ”D-H” (Data Hold) button again to return to normal operation.


Battery Replacement

Use a coin to open the compartment. Replace with a (AB13) (1.5V LR44) battery and close the cover.


Field Calibration Procedures

1. The KM400AP can only be calibrated in an ice slurry (60% crushed ice and 40% tap water) or a water bath. Do not attempt to calibrate by any other method.

2. Immerse the thermometer stem to at least 1/2 of its length in the ice slurry.

3. Wait until the reading stabilizes (typically ±1° of 0 °C / ±2° of +32° F).

4. Press and hold the D-H button for 8 seconds to initiate calibration.

5. Calibration is displayed for two seconds, and calibration at 0 °C / +32 °F is complete.

6. Remove the thermometer from the ice water and continue measuring.

Note: CAL is displayed when the D-H button is pressed for 8 seconds, but the thermometer will not calibrate unless the probe is immersed in ice water.

 

 